Labrador Handheld GC

Labrador Handheld GC

Portable handheld gas chromatograph for detecting VOCs and other contaminants in air, soil, water
Labrador Handheld GC
The Labrador Handheld GC brings laboratory-grade gas chromatography directly to the field, allowing environmental professionals to detect VOCs and contaminants in air, soil, and water within minutes. Built for real-time, on-site analysis, it reduces dependence on slow and costly off-site labs, helping teams respond immediately to contamination risks, maintain compliance, and make decisions faster. With parts-per-billion sensitivity and results in as little as 3 minutes, it provides actionable data before delays that escalate into additional equipment rental fees, regulatory fines, environmental damage, or loss of community trust.

Features

featureReal-time data
featureRugged & Portable
featureAnalyze VOCs in air, water, and soil
featureMinimal training required

On-site environmental analysis for air, water, and soil.

Real-time on-site analysis of VOCs with parts per billion (ppb) level sensitivity

Application

list_alt_check

Rapid Benzene Compliance

Instantly screen specific "hot spots" for Benzene and aromatic hydrocarbons, ensuring real-time adherence to exposure limits.
water

On-site Groundwater Screening

Screen purge water or groundwater for BTEX immediately using headspace analysis, providing instant feedback.
propane

Underground Storage Tank (UST) Assessment

Quickly delineate soil contamination boundaries during tank removal, using field purge-and-trap methods.
map

Spill Perimeter Mapping

Rapidly map the outer edges of a chemical spill plume to establish safe zones and work areas for emergency response teams.
nest_eco_leaf

Remediation Monitoring

Rapidly identify the precise location and extent of contaminated soil and groundwater, then track cleanup progress in real time with laboratory-quality field analysis.
school

Hands-on Education and Research

Empower universities, research institutions, and field teams with high-volume, real-time data collection using laboratory-grade analysis in the field.

Specifications

Trace level detection of VOCs
Photoionization Detector
ppb or ppbv
10.6 eV
2 orders of magnitude
3 - 10 minutes
5 minutes
Lasts upto 3 weeks
>650,000 analyses
Easy to use for air, water, and soil
Base Unit 6.80 kg (15 lb)
29.2cm W x 41.7cm D x 40.4cm H (ll.5"" W x 16.4"" D x 15.9"" H)
0° to 50°C
~95% non- condensing
7" Sunlight Readable Capacitive HDMI TFT LCD Module
24 V, 6Ah battery or 24 V DC supply
4 hours
Thermal desorption
Purge and trap